Küttelahendus uuele või renoveeritavale majale. Vajab vaid külmiku suurust põrandapinda.
UUS MUDEL.
Maja või ridaelamu küte ja soe tarbevesi
Integreeritud RST mahuti 250l
Juhib kütte ja tarbevee temperatuuri
Küttevee reguleerimisgraafik välisõhu järgi
Juhitav backup tarbeveele 1,8+3 kW,küttele 3 kW
WIFI
The monoblock unit (MBW) has similar data with split model (SW)
Model | AWT9-V6-SW/MBW | |
---|---|---|
Power supply | V | 230V/1phase |
Refrigerant | R410A | |
Max heating capacity (1) | kW | 10,1 |
COP (1) | 4,03 | |
Heating capacity (1) | kW | 4,33-10,10 |
Heating power input min/max (1) | W | 975-2153 |
COP min/max (1) | 4,02/4,65 | |
Max heating capacity (2) | kW | 9,53 |
COP (2) | 3,17 | |
Heating capacity (2) | kW | 4,19-9,53 |
Heating power input min/max (2) | W | 1230-2990 |
COP min/max (2) | 3,12/3,55 | |
Max cooling capacity (3) | kW | 6,84 |
EER (3) | 2,09 | |
Cooling capacity (3) | kW | 4,10-6,84 |
Cooling power input min/max (3) | W | 1230-3280 |
EER min/max (3) | 2,09/3,32 | |
Compressor | Twin rotary | |
Fan airflow | m3/h | 3000 |
Fan rated power | W | 76 |
Noise level indoor/outdoor | dB(A) | 35/56 |
Water Side Heat Exchanger | Plate Heat Exchanger | |
Heat Exchanger water pressure drop | kPa | 30 |
Water pump max water head | m | 7,5 |
Water volume | l | 250 |
Range of setting temperature** | C | 30-52-75** |
Hot water capacity* | l/h | 240 |
Min ambient temperature for compressor | C | -25 |
Control of small DHW electric heater | kW | 2 kW auto |
Control of electric heater (not limited with -25C) | kW | 6 kW auto/9 kW manual |
Water pipe connection | inch | 1 |
Refrigerant pipe connection | inch | 3/8, 1/2 |
(1) Heating condition: Water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
(2) Heating condition: Water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
(3) Cooling condition: Water inlet/outlet temperature: 23℃/18℃, Ambient temperature: 35℃;
(4) Cooling condition: Water inlet/outlet temperature: 12℃/7℃, Ambient temperature: 35℃.
(5) Marked with "*" means: Hot water capacity is based on testing condition: DB/WB 20℃/15℃, target
water temperature 50℃.
(6) Marked with "**" means: water temperature can reach 52 ℃ by heat pump, and reach 75℃ by using electric
heater simultaneously.
The specifications are subject to change without prior notice. For actual specifications of unit, please refer to
the stickers on the unit.
Performance tested as per EN14511-2007.